WA Part H9 Water use
Introduction to this Part
This Part contains requirements for reducing water use.
NCC Blurbs
The Objective is to reduce water demand by using water efficiently and minimising water wastage.
NCC SPTC Current
Efficient use of water
NCC ID
_6483c69c-899b-4b32-9938-d01204b571c3
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC SPTC Current
Potable water demand
NCC ID
_c5420f4f-28cd-483f-8a4e-90037e7243d6
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
A building must have features that, to the degree necessary, facilitate the efficient use of potable water appropriate to—
- the geographic location of the building; and
- the available potable water supply of the building; and
- the function and use of the building.
Applications
WA H9P1 only applies to Class 1 buildings, associated Class 10a buildings and swimming pools associated with a Class 1 building.
NCC SPTC Current
Water use efficiency
NCC ID
_fa53642f-2212-479f-85dd-18e4ae07c2da
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
A building, including any water holding structure, must have features that, to the degree necessary, prevent excessive loss of potable water appropriate to—
- the geographic location of the building; and
- the available potable water supply for the building; and
- the function and use of the building; and
- the effects of permanent features such as topography, structures and buildings.
Applications
WA H9P2 only applies to Class 1 buildings, associated Class 10a buildings and swimming pools associated with a Class 1 building.
NCC SPTC Current
Water loss prevention
NCC ID
_8e282e86-1a06-4f8c-8d0c-65845467496f
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
A building must have features that, to the degree necessary, facilitate the efficient use of heated water appropriate to—
- the geographic location of the building; and
- the available heated water supply for the building; and
- the function and use of the building.
Applications
WA H9P3 only applies to Class 1 buildings, associated Class 10a buildings and swimming pools associated with a Class 1 building.
NCC Title
Heated water use efficiency
NCC SPTC Current
Heated water use efficiency
NCC ID
_5b37ead5-3c23-46d3-9c0a-ee06ca77ddc8
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
Deemed-to-Satisfy Provisions
NCC Title
Deemed-to-Satisfy Provisions
NCC SPTC Current
Deemed-to-Satisfy Provisions
NCC ID
_04308cba-2f1e-4c50-b632-66a9c2106c2e
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
(1) All tap fittings other than bath outlets and garden taps must be a minimum of 4 stars WELS rated.
(2) All showerheads must be a minimum of 3 stars WELS rated.
(3) All sanitary flushing systems must be a minimum of 4 star WELS rated dual flush.
NCC SPTC Current
Water use efficiency
NCC ID
_f38025af-1709-4c80-b879-f4dd523d04e1
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
An outdoor private swimming pool or spa associated with a Class 1 building must be supplied with a cover, blanket or the like that—
- is deigned to reduce water evaporation; and
- is accredited under the Smart Approved Watermark Scheme governed by the Australian Water Association, the Irrigation Association of Australia, the Nursery and Garden Industry Australia and the Water Services Association of Australia.
NCC Title
Swimming pool covers and blankets
NCC SPTC Current
Swimming pool covers and blankets
NCC ID
_28a80c20-b6a5-4400-9263-b64d8b1564d6
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c
NCC Blurbs
(1) All internal heated water outlets (such as taps, showers and washing machine water supply fittings) must be connected to a heated water system or a recirculating heated water system with pipes installed and insulated in accordance with AS/NZS 3500: Plumbing and Drainage, Part 4 Heated Water Services.
(2) The pipe from the heated water system or recirculating heated water system to the furthest heated water outlet must not be more than 20 m in length or 2 litres of internal volume.
NCC Title
Heated water use efficiency
NCC SPTC Current
Heated water use efficiency
NCC ID
_ff4e4847-4c03-4a92-a453-f0aea17e1ead
Building Classes
2,3,4,5,6,7a,7b,8,9a,9b,9c