NCC 2022 Volume Three - Plumbing Code of Australia
Search the National Construction Code editions
3
Specification 3 Fire hazard propertiesSpecification 3 Fire hazard properties
S3C1
Scope
2019: Sch. 6: 1
This Specification sets out the procedures for determining the fire hazard properties of assemblies tested to AS/NZS 1530.3.
Assemblies
S3C2
General requirement
2019: Sch. 6: 2.1
The fire hazard properties of assemblies and their ability to screen their core materials as required under Specification 7 must be determined by testing in accordance with S3C3 to S3C6.
S3C3
Form of test
2019: Sch. 6: 2.2
Tests must be carried out in accordance with—
S3C4
Test specimens
2019: Sch. 6: 2.3
Test specimens must incorporate—
S3C5
Concession
2019: Sch. 6: 2.4
S3C4 does not apply to joints, perforations, recesses or the like that are larger than those in the proposed application and have already been tested in the particular form of construction concerned and found to comply with the conditions of the test.
S3C6
Smaller specimen permitted
2019: Sch. 6: 2.5
A testing laboratory may carry out the test specified in S3C3(b) at pilot scale if a specimen (which must be not less than 900 mm x 900 mm) will adequately represent the proposed construction in the building, but the results of that test do not apply to construction larger than limits defined by the laboratory conducting the pilot examination.