(1) A low risk liquid trade waste appliance must—
- be located as close as practicable to the fixtures that it serves and if of the portable type must be installed above ground; and
- be fitted with a cover which is able to withstand vehicular or pedestrian traffic or other loads likely to be imposed on it and is readily removable by one person; and
- be constructed of materials suitable for the nature of the wastes likely to be discharged through the appliance.
(2) A low risk liquid trade waste appliance must—
- if fitted with an airtight cover, be provided with a DN 32, DN 50 or DN 80 sized vent as nominated by the relevant Network Utility Operator; and
- be provided with the following outlet ventilation—
- if installed outside a building, a DN 100 sized riser off a disconnector gully in accordance with clause 4.6.2 of AS/NZS 3500.2;
- if not of the portable type and installed inside a building, a DN 50 sized vent off a disconnector gully in accordance with clause 4.6.5 of AS/NZS 3500.2; and
- if of the portable type installed inside a building, a DN 50 sized vent off a DN 80 sized trap riser in accordance with clause 4.6.5 of AS/NZS 3500.2.
(3) If a low risk liquid trade waste appliance and outlet vent are interconnected, the interconnection must be in accordance with clause 6.9.3 of AS/NZS 3500.2.
(4) The outlet from a low risk liquid trade waste appliance must—
- if of the portable type receiving a hydraulic loading of up to 5 fixture units, be a minimum size of DN 50; or
- if of the portable type receiving a hydraulic loading of more than 5 fixture units, be a minimum size of DN 80; or
- in cases other than that in (a) or (b), be a minimum size of DN 100; and
- have a separate trap, of the same size as the outlet pipe, installed at its outlet.
(5) In this clause hydraulic loading means the rate of discharge imposed on a sanitary plumbing installation and is measured in fixture units; low risk liquid trade waste means water-borne discharges other than sewage that are classified by an Authority within the meaning of the Water Act 1989 as being of low risk from causing harm to the environment and the assets of that Authority; low risk liquid trade waste appliance means an appliance that traps and partially treats low risk liquid trade waste and prevents it from entering the sewerage system.
Notes
The relevant Authority under the Water Act 1989 or the holder of a licence under the Water Industry Act 1994 may specify conditions of connection to a sewer for low risk trade waste to enter that sewer and may also require that the waste passes through a low risk liquid trade waste appliance of a type nominated by the Authority or holder of a licence before it enters the sewer.