10.6
Part 10.6 VentilationPart 10.6 Ventilation
10.6.1
Application
New for 2022
10.6.2
Ventilation requirements
2019: 3.8.5.2
Ventilation must be provided to a habitable room, sanitary compartment, bathroom, shower room, laundry and any other room occupied by a person for any purpose by any of the following means:
The ventilating area of a window is measured as the size of the openable sash of the window. This is the case regardless of the type of window, i.e. whether it is an awning, casement or sliding window and irrespective of the restrictions on the openable sash.
10.6.2(b) permits a room’s required ventilation to be ‘borrowed’ from an adjoining room, i.e. an adjoining room’s ventilation can be used to help make up the total amount of ventilation required.
The use of borrowed ventilation is acceptable if the provisions of 10.6.2(b) are applied to the subject room and to the total area of each relevant room.
10.6.3
Location of sanitary compartments
2019: 3.8.5.3
A sanitary compartment must not open directly into a kitchen or pantry unless—