Part 5.4 Unreinforced single leaf masonryPart 5.4 Unreinforced single leaf masonry
5.4.1
Application of Part 5.4
New for 2022
5.4.2
External walls
New for 2022
Element | Symbol used in Figure 5.4.2b | Thickness of wall (T) | |
---|---|---|---|
90 | 110 | ||
Pier size (minimum) (not more than N2) | A x B | 290 x 190 (800 spacing) | 350 x 230 (1150 spacing) |
Pier size (minimum) (not more than N3) | A x B | 290 x 290 (700 spacing) | 350 x 350 (1050 spacing) |
Spacing of returns (maximum) | S | 700 | 1050 |
Height (maximum) | H | 2400 | 2700 |
Element | Symbol used in Figure 5.4.2c | Thickness of wall (T) | |||
---|---|---|---|---|---|
90 | 110 | 140 | 190 | ||
Return length (minimum) | R | 450 | 450 | – | – |
Spacing of returns (maximum) (N2) | S | 1050 | 1300 | – | – |
Spacing of returns (maximum) (N3) | S | 600 | 750 | – | – |
Height (maximum) | H | 2400 | 2400 | 1700 (N2) | 2300 (N2) |
Wall thickness (mm) | Pier thickness (mm) | Pier width (mm) | Spacing (mm) for wind class | |
---|---|---|---|---|
N1 | N2 | |||
90 | 190 | 290 | 1000 | 600 |
90 | 290 | 190 | 1700 | 1200 |
90 | 290 | 290 | 2600 | 1800 |
110 | 230 | 230 | 1320 | 840 |
110 | 230 | 350 | 2040 | 1320 |
110 | 350 | 230 | 3240 | 2160 |
110 | 350 | 350 | 4920 | 3360 |
Wall thickness (mm) | Pier thickness (mm) | Pier width (mm) | Spacing (mm) for wind class | |
---|---|---|---|---|
N1 | N2 | |||
90 | 190 | 290 | 700 | 500 |
90 | 290 | 190 | 1300 | 900 |
90 | 290 | 290 | 2000 | 1400 |
110 | 230 | 230 | 960 | 600 |
110 | 230 | 350 | 1440 | 960 |
110 | 350 | 230 | 2520 | 1680 |
110 | 350 | 350 | 3840 | 2520 |
5.4.3
Internal walls
New for 2022
Internal masonry walls must be engaged with other walls, must comply with the relevant provisions of this Part and must be—
A full height door frame or stud fastened at the roof framing and tied to the wall at 300 mm centres can be considered equivalent to a return wall.
5.4.4
Vertical articulation joints
New for 2022
Vertical articulation joints must be provided in accordance with 5.6.8.
5.4.5
Damp-proof courses and flashing materials
New for 2022
Where required, damp-proof courses and flashing must be provided in accordance with 5.7.3 and 5.7.4.